Furnace making noise
A furnace making noise is usually pointing at something specific. Whistling often comes from a clogged filter or closed vents, rattling from a loose panel, screw or duct, and squealing from a worn blower belt or a motor that needs attention. A loud bang or boom when the burners light is different. That's usually delayed ignition from dirty burners, and it's a job for a technician, not a DIY fix. The sound tells you where to look. Air sounds are easy fixes; booms at ignition are a call to a pro.


Normal furnace sounds and noisy ones
A gas forced-air furnace has a few parts that make sound on every cycle. An inducer fan starts first to pull exhaust out, an igniter lights the burners, and once the heat exchanger warms up, the blower pushes air through the ducts. A click, a soft whoosh from the burners and a steady hum from the blower are normal. Ducts also tick and pop a little as the metal heats and cools.
New or louder sounds are the ones to track down. Air noises usually mean the system is starved for air, metal noises usually mean something has worked loose, and motor noises mean a belt or bearing is wearing out. Most of the easy causes are on the air side and outside the furnace cabinet. Noises from the burners or the motors themselves are where a technician comes in.
Common causes of furnace noise
Starved airflow whistles and roars.
Sheet metal rattles, buzzes and pops.
The blower squeals or grinds.
Gas builds up and lights with a boom.
| You hear | Likely cause | Start at |
|---|---|---|
| Whistling at the filter or vents | Dirty filter or closed vents | Step 2 |
| Booming in the ducts at blower start | Pressure or a flexing duct | Step 3 |
| Rattling or buzzing | Loose panel, screw or strap | Step 4 |
| Popping in the ducts | Ducts expanding or flexing | Step 5 |
| Squealing or scraping while it runs | Belt or blower wheel | Step 6 |
| Bang or boom when burners light | Delayed ignition | Step 7 |
| Grinding from a motor | Worn motor bearings | Step 7 |
Let's fix it
- Pin down the sound and when it happensStand near the furnace through a full cycle. Notice whether the noise starts when the inducer fan starts, when the burners light, while the blower runs, or after it shuts off, and whether it comes from the furnace or out in the ducts. A bang or boom right as the burners light is delayed ignition; turn the furnace off at the thermostat and skip to the last step. Record a short video on your phone to remember the sound.

- Replace a dirty filterA clogged filter makes the blower strain, which can sound like whistling around the filter slot or a louder roar from the vents. Slide the filter out and hold it up to a light; if you can't see light through it, replace it with the same size, with the airflow arrow pointing toward the furnace. Make sure the filter cover is on so air isn't whistling in around the slot. We have a guide for changing an HVAC air filter for sizes and schedules.

- Open vents and clear returnsClosing too many supply registers, or blocking return grilles with furniture or rugs, raises the pressure in the ducts. That can cause whistling at the registers and booming in the ducts when the blower starts. Open the registers in every room, clear anything in front of the return grilles, and listen again.

- Tighten loose panels and screwsRattles and buzzing usually come from loose sheet metal. Turn the furnace off at the thermostat, then check that the furnace's access panels are fully seated and their screws snug. Look for a loose screw, a loose duct strap or a rattling flue pipe connection, and tighten it. If a flue pipe joint has pulled apart or is rusted through, leave the furnace off and call a technician, since it can leak carbon monoxide. A strip of adhesive foam tape between two metal parts that touch can stop a buzz, but never block a vent opening or tape over the flue pipe.

- Check the ductsA pop or bang in the ducts when the blower starts or stops is often a flat section of duct flexing in and out, sometimes called oil canning. Follow the ducts you can reach in the basement or attic and look for loose joints, hanging straps that have come loose, and sections that flex when you push on them. Seal loose joints with foil HVAC tape, not cloth duct tape. If a large duct keeps booming, a technician can add a stiffening bend or brace.

- Look at the blower with the power offSquealing or scraping while the blower runs points to the blower. Switch off the furnace's power switch, usually on the side of the furnace or on a nearby wall, and its breaker, then confirm the power is off with a voltage tester. Remove the blower door. Look for debris inside the blower wheel and for a wheel that's loose on its shaft. On an older belt-drive blower, check the belt for cracks, glazing or looseness and replace it with one of the same size, set to the tension in the manual. A few older motors have oil ports; oil them only if the manual says to. Put the door back before restoring power.

- Call a technician for booms, grinding or screechingSome noises need a pro. A bang or boom when the burners light, grinding or screeching from the blower or inducer motor, a rumble after the burners shut off, or flames that lift, roll or look ragged all need service. Leave the furnace off until it's checked, and make sure your carbon monoxide alarms work; see the guide for a carbon monoxide alarm beeping. If you smell gas, leave the house and call the gas company from outside.

Watch it done
- No whistling, rattles or squeals through a full cycle
- Burners light quietly
- Registers blow steady air
Still banging at ignition? Leave it off and call a technician.
If it's more than noise
If the furnace runs but blows cold air, check our guide for a furnace blowing cold air.
If it turns on and off every few minutes, there's a separate guide for a furnace short cycling.
What a pro typically charges (a rough estimate; prices vary by area): An HVAC service call typically costs $100–$200. A blower belt usually runs $100–$250 installed, cleaning burners for delayed ignition $150–$300, an inducer motor $300–$700, and a blower motor $400–$900 or more.
Find an HVAC technician near youSomething else going on?
Furnace noise questions
Why is my furnace making a loud noise?
Whistling usually means a dirty filter or closed vents, rattling a loose panel or duct, and squealing a belt or motor. A bang when the burners light needs a technician.
Is a banging furnace dangerous?
A bang or boom when the burners light is delayed ignition and should be checked soon. Turn the furnace off and call for service.
Why do my heating ducts pop?
Metal ducts expand and contract as they heat and cool, and flat sections can flex when the blower starts. Small pops are normal; loud booms are worth checking.
Can a dirty filter make a furnace noisy?
Yes. A clogged filter starves the blower for air, which can cause whistling and a louder roar.
Why is my furnace squealing?
Usually a worn blower belt or a motor that needs attention. Check the belt and blower wheel with the power off.