Heat pump blowing cold air

A heat pump blowing cold air in winter is often doing exactly what it's designed to do. During a defrost cycle it briefly sends cooler air inside, and even normal heat pump air feels cooler than furnace air. Start by ruling out those two, then check the thermostat, the filter and the outdoor unit. If the outdoor unit runs but the air stays cold for a long stretch, the problem may be the reversing valve or refrigerant, and that's a job for an HVAC technician. Heat pump air feels cooler than furnace air even when it's working. Measure it before you worry.

Clearing leaves and snow from the base of a frosty outdoor heat pump in defrost
A heat pump in defrost mode can blow cool air for a few minutes.
Quick answerFirst rule out a defrost cycle and check the air temperature at a vent; 85 to 95 degrees is normal. Then set the thermostat to HEAT with the fan on AUTO, replace a dirty filter, clear snow and ice from the outdoor unit, and check its breaker and disconnect.
Worth checking firstLook at the outdoor unit. If its fan has stopped and it's steaming, it's just defrosting, and the cool air will stop in a few minutes.

Good to knowNo toolbox needed

Easy15–45 min$0–40
A heat pump system in winter: inside, the thermostat set to HEAT with the fan on AUTO, the indoor air handler with its filter slot and the supply register, and the breaker panel with the heat pump's double breaker. Outside, the outdoor unit sits on its pad with snow cleared about two feet around it, steam rising from the coil during a normal defrost cycle, and the outdoor disconnect switched off before anyone touches the unit.
Cool air during a defrost cycle (5) is normal. Otherwise check the thermostat (1), the filter (2), the space around the outdoor unit (8) and its power (6, 7).

Why a heat pump blows cool air

A heat pump doesn't burn fuel. In heating mode it pulls heat out of the outdoor air and pumps it inside, using a reversing valve to run the same refrigerant loop it uses for cooling in the opposite direction. Because it moves heat rather than making it, the air at the registers is warm but not hot, usually somewhere around 85–95°F.

In cold, damp weather, frost builds up on the outdoor coil. The system clears it by switching briefly into cooling mode, which warms the outdoor coil. While that happens you may feel cooler air indoors and see steam rising from the outdoor unit. Most systems also have backup electric heat, called auxiliary or emergency heat, for very cold weather.

Common causes of cold air

A normal defrost cycle

The system briefly runs in cooling mode to melt frost off the outdoor coil.

A thermostat setting

COOL mode, a low setpoint or the fan set to ON.

A blocked or iced outdoor unit

Snow, leaves or ice stop it from pulling heat from the air.

A reversing valve or refrigerant problem

The system can't switch into heating or doesn't have enough refrigerant to move heat.

What's happening?
You noticeLikely causeStart at
Steam from outdoor unit, cool air brieflyNormal defrost cycleStep 1
Air feels lukewarm, not hotNormal heat pump air temperatureStep 2
Cold air steadily, outdoor unit runningThermostat in COOL or wrong settingStep 3
Cool air between cyclesFan set to ONStep 4
Weak airflow from ventsDirty filterStep 6
Outdoor unit buried in snow or iceBlocked outdoor coilStep 7
Indoor fan runs, outdoor unit silentTripped breaker or disconnect offStep 8
Power off and no chipping iceTurn off power at the breaker and the outdoor disconnect before touching anything inside the outdoor unit. Never chip or pry ice off the coil, and never use a heat gun or open flame on it. If a breaker keeps tripping, don't keep resetting it.

Let's fix it

0 of 8 done
  1. Rule out a defrost cycleGo outside and look at the outdoor unit. If the fan has stopped and you see steam or water dripping off the coil, it's defrosting. That usually lasts a few minutes up to about 15, and the air inside may feel cool until it finishes. If the cold air stops when the steam does, nothing is wrong.
    Outdoor heat pump unit with its fan stopped, steam rising and water dripping off the coil, next to a clock showing defrost usually lasts a few minutes up to about 15
  2. Measure the air temperatureHold a thermometer in a supply register near the indoor unit for a few minutes while the system is heating. Air in the 85–95°F range is normal for a heat pump, even though it can feel cool on your hand, especially if you're used to a furnace. If it reads close to room temperature or below, keep going.
    Thermometer held in a floor supply register while the heat pump runs, reading about 90 degrees, which is normal for a heat pump even if it feels cool
  3. Check the thermostat modeMake sure the thermostat is set to HEAT, not COOL or OFF, and that the setpoint is a few degrees above the room temperature. Replace the batteries if the display is dim. On a newly installed thermostat, the reversing valve setting (often labeled O/B) can be set the wrong way, which makes the system cool when you ask for heat; check the installer settings in the manual or have the installer look at it.
    Thermostat set to HEAT with the setpoint a few degrees above room temperature, next to fresh batteries for a dim display
  4. Set the fan to AUTOIf the fan is set to ON, the indoor blower runs all the time, including between heating cycles and during defrost. That moving air feels cool. Switch it to AUTO so the fan only runs while the system is actually heating.
    Thermostat with the fan switched from ON, which blows cool air between cycles, to AUTO so the blower runs only while heating
  5. Use emergency heat only as a stopgapEmergency heat (EM HEAT) shuts off the heat pump and runs only the electric backup strips. It's meant for when the outdoor unit is broken, and it's very expensive to run for long. If the house is getting cold while you wait for a repair, switch to it for comfort, then call a technician. Don't leave it on as the normal setting.
    Thermostat switched to EM HEAT, which runs only the costly electric backup strips, shown with a stack of money as a short-term fix while waiting for a technician
  6. Replace a dirty filterPull out the filter at the indoor unit or return grille and hold it up to a light. If you can barely see through it, replace it. A clogged filter cuts airflow, which lowers how much heat reaches the rooms and can make the system shut down on its safety controls.
    Dirty filter from the indoor unit held up to a light so almost no light passes through, next to a new clean filter
  7. Clear the outdoor unitTurn the system off at the thermostat. Brush snow and leaves away from the sides and top, and keep at least two feet clear around the unit. If the coil is encased in ice, don't chip at it, which can puncture the coil. Let it melt on its own or pour lukewarm water from a hose over it, then turn the system back on so it can run a defrost cycle. Drain and put away the hose afterward so it doesn't freeze. Also check that roof runoff isn't dripping onto the unit and refreezing.
    Something went wrong?
    • The coil is still iced after an hour or two Turn the system off and call a technician. Repeated icing can mean a defrost or refrigerant problem.
    Thermostat turned off and the outdoor disconnect switched off, then snow brushed gently off the top and sides of the heat pump by hand with a soft brush, with two feet cleared around it and no chipping at ice
  8. Check the outdoor unit's powerIf the indoor fan runs but the outdoor unit is silent, check your panel for a tripped breaker for the heat pump. It's usually a double breaker, and both handles trip together, so push them fully off and then back on. Also check that switch in the box near the outdoor unit is on. If the breaker trips again, leave it off and call a technician.
    Something went wrong?
    • The breaker trips again right away Leave it off and call a technician; there may be a short or a failing part in the outdoor unit.
    Breaker panel with the heat pump's double breaker tripped, pushed fully off and then back on, with a note to call a technician if it trips again

Watch it done

Top 3 Heat Pump ISSUES in Winter!By HVAC Guide for Homeowners on YouTube. Their method may vary a little from ours.
Watch on YouTube
How you'll know it's fixed
  • Air at the vents reads about 85 to 95 degrees while heating
  • The house reaches the set temperature
  • Cool air only shows up briefly during defrost

Air still near room temperature? Call a heat pump technician.

If it's still blowing cold

If the outdoor unit is running and isn't iced over but the air at the registers stays near room temperature, the system may be low on refrigerant or the reversing valve may be stuck. Both need a licensed technician.

If the house only goes cold during very cold snaps, the heat pump may be running past what it can supply and the backup heat may not be kicking in. A technician can check the auxiliary heat strips and the thermostat staging.

Keep the outdoor unit clearKeep the outdoor unit clear of snow all winter and change the filter regularly. A heat pump that can breathe on both ends heats better and defrosts faster.
Renting?If you rent, setting the thermostat and changing the filter are usually yours. Report a heat pump that stays cold.
Call an HVAC tech ifThe air stays cold well past a defrost cycle, the outdoor unit won't run, it stays iced up for hours, the breaker trips again, or the system cools when it's set to heat. A stuck reversing valve, low refrigerant or a failed defrost control all need a technician.Fix it yourself or call? Compare the cost →

What a pro typically charges (a rough estimate; prices vary by area): An HVAC service call typically runs $100–$250. Fixing a refrigerant leak and recharging often costs $300–$1,500, a defrost control board $250–$600, and a reversing valve replacement $1,000–$2,500 installed.

Find an HVAC technician near you

Something else going on?

Heat pump cold air questions

Why is my heat pump blowing cold air in winter?

Often it's a defrost cycle, which briefly sends cooler air in while the outdoor coil melts off frost.

How warm should air from a heat pump feel?

Usually around 85–95°F at the register. It feels cooler than furnace air but is still heating.

When should I use emergency heat?

Only when the outdoor unit isn't working and you're waiting for a repair. It's expensive to run.

Is steam coming from my heat pump normal?

Yes, during defrost. Smoke or a burning smell is not, so turn it off and call a technician.

Why does my heat pump blow cool air for a few minutes?

It's probably a defrost cycle, when the unit briefly sends cooler air inside while it melts frost off the outdoor coil. That's normal.

Reader reports

Did this fix work for you?

Tell the next person how it went. Your numbers are added to the totals anonymously; tips are read by our team before they appear.

How did it go?
Reader Q&A

Questions from readers

No questions on this guide yet. If you're stuck, ask below. Useful questions and answers get added here for the next person.

Ask a question

More from us

We read every question before anything is published, and we never show names or emails. Please leave out personal details. Privacy

About the authors

GrabTheHammer Team

  • No sponsored picks
  • Safety first
  • Tells you when to call a pro

We're a small team of writers and editors who check every guide against manufacturer instructions and common code requirements. Our goal is to help you understand the problem, tackle what you safely can and know when to call a pro.

Checked against: Manufacturer instructions for the parts and products involved, ENERGY STAR, U.S. Department of Energy.