Walls

Stop cold drafts from outlets and switches

Outlets and light switches on outside walls are small holes through the wall's insulation and air barrier. Cold outdoor air can find its way into the wall and out through the gaps around the electrical box and the slots in the cover plate. Foam gaskets that fit behind the cover plate block most of it, cost a few dollars for a pack, and take a few minutes per outlet. Sealing the gap around the box adds more. If cold air pours in, the wall itself may have a bigger leak worth finding.

Hands fitting a foam gasket around an outlet with the cover plate removed, while a thread of incense smoke shows the draft
With the breaker off, a foam gasket behind the plate blocks the draft.
Quick answerTurn off the breaker for the outlets you'll work on. Unscrew each cover plate, press a foam outlet or switch gasket over the outlet, and screw the plate back on snug. Seal any gap wider than about 1/8 inch between the box and the drywall with acrylic caulk. Push child-safety plugs into unused outlets on outside walls. Turn the breaker back on and test each outlet.
Worth checking firstOn a cold, windy day, hold the back of your hand or a lit incense stick a few inches from each outlet and switch on outside walls. Watch where the smoke wavers. That tells you which ones need sealing first.
Easy5 min per outlet$5–20
Side cutaway of an outside wall showing cold air moving from outside through the wall cavity, around the electrical box and out the cover plate slots, with a foam gasket behind the cover plate and caulk sealing the gap between box and drywall
Cold air (1) gets into the outside wall and leaks around the electrical box (2), out the gap at the drywall (3) and through the cover plate (4). A foam gasket (5) behind the plate and caulk in the gap block most of it.

Why outlets and switches let in cold air

A wall on the outside of the house has siding and sheathing on the outside, insulation in the middle and drywall on the inside. The drywall and paint act as part of the air barrier that keeps outdoor air from moving into the room. Every outlet and switch on that wall needs a hole cut in the drywall for its box, and the box itself often has knockouts, gaps where wires enter, and a small gap around its edge. Air that gets into the wall cavity from outside, through gaps in the siding, sheathing or at the top and bottom plates, follows the easiest path out, and those holes are an easy path.

Wind pushes air into the house on one side and pulls it out on the other, and warm air rising in the house pulls cold air in near the floor. That's why low outlets on windy sides feel the coldest. Foam gaskets made to fit behind the cover plate close the plate slots and edges, and caulk closes the gap between the box and drywall. Together they cut down most of the draft you feel. A strong, steady stream of cold air means the wall has a bigger opening or missing insulation, which sealing an outlet won't fully fix.

Why outlets feel drafty

Outlets on outside walls

They're holes through the wall's air barrier.

Gap around the box

Drywall was cut larger than the box.

Openings in the cover plate

Air passes through the slots and edges.

Unused outlet openings

Air passes through the outlet slots themselves.

Leaky or uninsulated wall

Air moves freely through the wall cavity.

What's happening?
You noticeLikely causeStart at
Not sure which outlets leakFind the draftsStep 1
Draft from an outlet or switchNeeds a gasketStep 3
Gap visible around the boxNeeds caulk or sealantStep 4
Cold air through unused outlet slotsNeeds safety plugsStep 5
Cold air pours in or the wall feels coldBigger air leak or missing insulationStep 6
Before removing any cover plateTurn the power offStep 2
Power off first, and don't block the boxTurn off the breaker for the outlets and switches you're working on, then test with a non-contact voltage tester or a lamp before removing cover plates. Don't use spray foam inside an electrical box, and don't stuff insulation into it. Use only foam gaskets made for outlets and switches, and caulk only around the outside edge of the box. If you see scorched wires, loose outlets, aluminum wiring or a box that moves in the wall, stop and call an electrician.

Let's fix it

0 of 6 done
  1. Find the drafty outlets and switchesChoose a cold, windy day. Close windows and doors, and turn on bathroom and kitchen exhaust fans to pull air in from outside, which makes leaks easier to feel. Hold the back of your hand, a damp fingertip or a lit incense stick 2 to 3 inches from each outlet and switch on outside walls. Smoke that wavers or blows sideways, or a cool feeling on your hand, marks a leak. Make a list or put a small piece of painter's tape on each one. Indoor walls rarely leak; start with outside walls and the windy side of the house.
    Lit incense stick held near an outlet on an outside wall, with its smoke blowing sideways from the cold draft
  2. Turn off the powerFind the breaker for the room in your electrical panel and switch it off. Panel labels can be wrong, so test: plug a lamp into the outlet, or hold a non-contact voltage tester to the outlet slots and switch screws, to confirm there's no power. A switch box can contain wires from more than one circuit, so test each one. You only need to flip the breaker, not open the panel. Keep a flashlight handy if the lights in that room go off too.
    Hand switching off a labeled breaker, then a voltage tester confirming no power at the outlet
  3. Add foam gaskets behind the cover platesUnscrew the cover plate's center screw or screws and take the plate off. Use foam gaskets made for outlets or switches; they come precut, usually in packs of a dozen or more for a few dollars. Press the gasket over the outlet or switch so its cutouts line up with the device, and the outer edge lies flat on the wall. Put the cover plate back on and tighten the screws until snug. Don't overtighten, which cracks plastic plates. If a plate won't sit flat with the gasket, trim the gasket edges with scissors. Switch gaskets and outlet gaskets have different cutouts, so count each type on your list before you buy. If you see a gap around the box, do the next step before putting the gasket and plate on.
    Something went wrong?
    • The plate won't sit flat The gasket's cutouts may not line up, or the outlet sticks out. Re-seat the gasket, and if the outlet sits proud of the wall, have an electrician adjust it.
    • The cover plate cracked Replace it; plates are inexpensive. Snug the screws only until the plate stops moving.
    Precut foam gasket being pressed over a duplex outlet before the cover plate is screwed back on
  4. Seal the gap around the boxWith the plate off, look at the edge where the drywall meets the electrical box. If there's a gap wider than about 1/8 inch, run a thin bead of paintable acrylic latex caulk around the outside of the box, filling the gap between the box and drywall. Keep caulk out of the box and off the outlet or switch. For gaps wider than about 1/4 inch, the drywall may need patching first, or the box may need an extender ring, which an electrician can install. Let the caulk dry for the time on the tube, often 30 minutes to an hour, before putting the plate back on.
    Something went wrong?
    • The gap is bigger than the cover plate Don't fill it with foam. Patch the drywall around the box first; see the drywall patch guide, or have an electrician fit an extender ring.
    Thin bead of caulk run around the outside edge of an electrical box where it meets the drywall, with the cover plate off
  5. Plug unused outletsAir also leaks through the slots of outlets you don't use. Push plastic child-safety plugs into unused outlets on outside walls; they block the slots and keep small fingers out. Some outlet gaskets come with matching plugs. Once everything is sealed, turn the breaker back on and test each outlet with a lamp and each switch with its light. Check again on the next cold, windy day with your hand or the incense stick, since you may find a few outlets you missed. Leave plugs out of outlets you use every day, since you'll just lose them; the gasket behind the plate does most of the work.
    Child-safety plugs pushed into the slots of an unused outlet, then a lamp plugged into another outlet to test it
  6. Look for bigger leaks if it's still coldIf cold air still pours out, or the wall around the outlet feels icy, the wall has a bigger problem than the outlet. Common culprits are gaps where siding, trim or a window meets the wall, a missing or settled section of insulation, or open framing at the top or bottom of the wall. Check the outside of that wall for gaps around pipes, vents and trim, and seal them with exterior caulk. An energy audit, often subsidized by utility companies, uses a blower door and infrared camera to find leaks and missing insulation precisely. Fixing those outside gaps often does more for comfort than the outlet gaskets alone, because the cold air was getting into the wall there first.
    Outside of a house wall with gaps around a vent and trim being sealed with exterior caulk

Watch it done

How to Seal Up Drafty Outlets and Switches | The Fixer ClipsBy The Fixer 2 on YouTube. Their method may vary a little from ours.
Watch on YouTube
How you'll know it's fixed
  • No noticeable draft at outlets and switches on a windy day
  • Cover plates sit flat and snug
  • Every outlet and switch works after the breaker is back on

Still cold? The wall may need sealing outside or more insulation.

If it comes back

Gaskets last for years, but they can get compressed if plates are removed often. Replace them when you change cover plates or paint.

Windows and doors usually leak far more air than outlets. See how to stop drafts around windows and how to weatherstrip an exterior door.

If an outlet is loose in the wall, plugs fall out, or it feels warm, that's a different problem. See how to replace an outlet, or call an electrician.

Do baseboard and window walls firstOutlets on the windy side of the house and near the floor usually leak the most, since cold air sinks and wind pushes on that wall.
Renting?Gaskets and safety plugs are small, reversible fixes most landlords are fine with. Ask before caulking, and report loose or warm outlets.
Call an electrician ifAn outlet or switch is loose in the wall, warm, scorched or buzzing, the box is recessed and needs an extender, or the wiring looks old, cloth-covered or aluminum. For big air leaks, an energy auditor or insulation contractor can help.Fix it yourself or call? Compare the cost →

What a pro typically charges (a rough estimate; prices vary by area): An electrician typically charges about $100–$250 to fix a loose or recessed outlet. A home energy audit often costs about $200–$500, and some utilities offer it free or discounted.

Find an energy auditor near you

Something else going on?

Drafty outlet questions

Why is cold air coming out of my outlets?

Outlets on outside walls are holes in the wall's air barrier. Outdoor air gets into the wall and leaks out around the box and through the cover plate.

Do outlet gaskets really work?

They block much of the air leaking through the cover plate. Sealing the gap around the box and other leaks in the wall helps more.

Is it safe to put foam insulation in an outlet box?

No. Don't use spray foam or insulation inside the box. Use foam gaskets made for outlets and caulk only around the outside edge.

Do I need to turn off power to install outlet gaskets?

Yes. Turn off the breaker and test that the outlet is dead before removing the cover plate.

Should I seal outlets on interior walls?

Usually it isn't needed. Interior walls rarely leak outdoor air. Focus on outlets on outside walls.

Reader reports

Did this fix work for you?

Tell the next person how it went. Your numbers are added to the totals anonymously; tips are read by our team before they appear.

How did it go?
Reader Q&A

Questions from readers

No questions on this guide yet. If you're stuck, ask below. Useful questions and answers get added here for the next person.

Ask a question

We read every question before anything is published, and we never show names or emails. Please leave out personal details. PrivacyAccessibility

About the authors

GrabTheHammer Team

  • No sponsored picks
  • Safety first
  • Tells you when to call a pro

We're a small team of writers and editors who check every guide against manufacturer instructions and common code requirements. Our goal is to help you understand the problem, tackle what you safely can and know when to call a pro.

Checked against: U.S. Department of Energy and ENERGY STAR air sealing guidance, and outlet gasket manufacturer instructions.

How we write and review →
A helpful next stepStop drafts around windowsSeal the windows next; they usually leak more.